close
Pressure Protection
68 items
EH/0S
EH/0S
The PROTEGO® EH/0S vent cap allows vessels which are not pressurized to vent. This device prevents rain and dirt entering the vent line. The PROTEGO® EH/0S vent cap is not flame transmission proof. It is often used in combination with detonation flame arresters, when those are used in vent lines, installed at a position which creates a long run up distance from the end of the vent line to prevent endurance burning. The PROTEGO® EH/0S will then be installed at the end of that vent line to prevent particles or rain from entering the line.
- USD
ER-V-LP
ER-V-LP
The PROTEGO® type ER-V-LP valve is a sophisticated pressure relief valve for applications in which a high flow efficiency is of the essence. It is primarily used as an emergency pressure relief valve on storage tanks, vessels, silos, and process engineering equipment. It offers reliable protection against excessive overpressure and prevents excessive product loss at pressures as high as close to the set pressure. It is designed to release particularly large quantities to prevent the vessel from rupturing in an emergency case.
- USD
ER/VH
ER/VH
The ER/VH type PROTEGO® valve is a highly developed emergency pressure relief valve with high flow capacity. It is primarily used as a device for emergency pressure relief for storage tanks, containers, silos, and process engineering equipment. It offers reliable protection against overpressure and prevents excessive product vapor loss close to the set pressure. It is designed to release particularly large amounts to prevent the vessel from rupturing in an emergency case. Higher set pressures are achieved by a lever with a lockable weight load. The position of the weight is set at the factory. Starting at DN 500, the devices can also be used as manhole covers.
- USD
FA-CN-IIA, IIB3
FA-CN-IIA, IIB3
The PROTEGO® FA-CN in-line deflagration flame arrester is a compact design utilizing an easy access cover for easy maintenance. The PROTEGO® flame arrester unit can easily be removed and cleaned in just a few simple steps without having to disassemble the pipe. When installing the deflagration flame arrester, make sure that the distance between potential ignition sources and the location of the installed device does not exceed the L/D ratio (pipe length/pipe diameter) for which the device was tested. According to EN ISO 16852, this device is approved for a (L/D)max ratio of 50.
- USD
FA-E
FA-E
The PROTEGO® FA-E series of in-line deflagration flame arresters is designed with an eccentric housing to automatically drain condensate build up in the housing. Due to its eccentric design, the device can be installed in pipelines that run close to floors or walls and low points to prevent the build-up of condensate. When installing the deflagration flame arrester, make sure that the distance between potential ignition sources and the location of the installed device does not exceed the L/D ratio (pipe length/pipe diameter) for which the device was approved. According to EN ISO 16852, the installation limits are (L/D)max ? 50 for deflagration flame arresters of explosion groups IIA and IIB3 (NEC groups D to C) and (L/D)max ? 30 for explosion group IIC (NEC group B).
- USD
FA-G
FA-G
The compact design of the PROTEGO® FA-G in-line deflagration flame arrester makes it the state-of-the-art technology for installation in pipes with diameters of up to 2”. The devices are installed with minimal distance to the burner to prevent flashback into the fuel feed lines. When installing the deflagration flame arrester, make sure that the distance between potential ignition sources and the location of the installed device does not exceed the L/D ratio (pipe length/pipe diameter) for which the device was approved. As per EN ISO 16852, the L/D ratio is limited to (L/D)max ? 50 for deflagration flame arresters of explosion groups IIA and IIB3 (NEC groups D and C {MESG ? 0.65 mm}) and to (L/D)max ? 30 for explosion group IIC (NEC group B).
- USD
ValvKeep & ValvKeep Viewer
VKV
ValveKeep is the most powerful asset management software tool on the market designed to manage your valve population from cradle to grave. A fundamental role of Reliabilty and Asset Management is to track production losses and abnormally high maintanace cost and then find ways to reduce losses and high costs. VALVEKEEP (VK Viewer) gives the customer the ability to manage a complete collection of pressure releif valves, control valves, automated on/off valves or any type of valve into a single database for detailed analysis.
- USD
D-SVL-EB-IIA
D-SVL-EB-IIA
The deflagration-proof and endurance burning-proof D-SVL-EB type PROTEGO® valve is a highly developed pressure relief valve for large flows with an integrated flame arrester PROTEGO® EB. It is primarily used as a device for flame transmission-proof out-breathing on tanks, containers, and process equipment. The valve offers reliable protection against excess pressure and prevents product losses almost up to the set pressure; while at the same time protecting against atmospheric deflagration and endurance burning if stabilized burning occurs. The PROTEGO® flame arrester unit is designed to achieve minimum pressure drop with maximum safety. PROTEGO® D-SVL-EB valves are available for substances for substances of explosion group IIA (NEC group D MESG > 0.9 mm).
- USD
DR/ES, DN 1/4 - 3/4
DR/ES, DN 1/4 - 3/4
The PROTEGO® DR/ES series in-line detonation flame arrester with connection size up to ¾“ is ideal for installation in small pipes and to protect equipment such as gas analyzers. The device protects against deflagrations and stable detonations. It can be installed anywhere in the pipe no matter what the distance is from the potential ignition source. The small and compact flame arrester has a right angle design.